Our primary servers are located at the edge of downtown Dallas, TX in the Colo4Dallas 28,000 square foot raised floor facility which features redundant UPS systems with diesel generator backups, fire detection and suppression systems, closed circuit monitoring of all areas and entrances, card key access, 24 hour manned security, redundant HVAC systems and fiber connectivity from 12 separate providers. The data center has been engineered to avoid any single point of failure in our connectivity, power, or HVAC.

Dallas is an ideal location for our primary data center location because of the absence of natural disasters and its central location to the Internet backbone connections from all across the United States.

Allentown
Our secondary location utilizes a private, secure facility in Allentown, PA.  The Allentown location was selected as a secondary LunaHost facility based on the provider's ability to provide fast response and for their experience in providing secure solutions to both business and government organizations.  Its close proximity to the New York metropolitan area while at the same time situated in an area less vulnerable to natural disasters make it an ideal location for clients needing to provide custom virtual machines or hosted applications.



 

Network

Dallas
Multiple carriers with diverse building entrances
Fully redundant Cisco architecture using 12008 and 7513 routers, with 5500 series switches
HSRP failover connections to Level3 and Time Warner
Dual network feeds to each server
100% Service Level Agreement

 

Allentown
Multiple carriers with diverse building entrances
Fully redundant Cisco architecture using 12008 and 7513 routers, with 5500 series switches
HSRP failover connections to CTSI/Frontier with backup connections to Verizon and Global Crossing
Dual network feeds to each server
100% Service Level Agreement





Power Systems

Dallas
Liebert and Powerware UPS with 120, 208, 220VAC available
Maintenance by-pass
2400 amps DC plant
100% diesel generator backup with auto start and auto transfer switch
Generator capacity equal to building utility service
A and B DC plants totally diverse
Fuel capacity exceeds 24 hours
Fuel delivery contract with 2-hour guarantee

Allentown
Liebert UPS with 120, 208, 220VAC available
Maintenance by-pass
2400 amps DC plant
100% diesel generator backup with auto start and auto transfer switch
Generator capacity equal to building utility service
Fuel capacity exceeds 24 hours
Fuel delivery contract with 2-hour guarantee




Environmental Controls

Dallas
Constant ambient air temperature of 68° (+/- 2°)
Liebert air handlers
Under-floor cooling
Humidity control via Liebert units

Allentown
Constant ambient air temperature of 68° (+/- 2°)
Liebert air handlers
Under-floor cooling
Humidity control via Liebert units



Security and Access

Dallas
24x7 on-site technicians
Biometric Scanners
Multiple layers of 24x7 security cameras, card readers, and key pads
Access to equipment area 24x7 via card key and key pads
Non-customers enter equipment area by escort only
All cabinets, cages, and suites are locking, with security upgrades available
Facilities are monitored with 24 hour recording and 5 day video storage

Allentown
24x7 technicians
Multiple layers of 24x7 security cameras, card readers, and key pads
Access to equipment area 24x7 via card key and key pads
Customers enter equipment area by escort only
All cabinets, cages, and suites are locking
Facilities are monitored with 24 hour recording and 5 day video storage


Fire Suppression Systems

Dallas and Allentown
Pre-action sprinkler rated for telecommunication equipment/computer room
Integrated smoke/heat detector system